<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-27 09-34-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 60 dBuV INFO
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 66 kHz 17075 0,1288
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 3,93 dBr 4,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INFO " F206 0 (No PTY) 1 0 0 0 9:33, 27.05.2024
RT
"09H-10H FRANCEINFO: - NEWS / INVITE - FRANCEINFO : L'INFO JUSTE."
AF EON
103.1, 105.5, 105.7 MHz F222, F207
FM Scope Station: 105.50 MHz, signal: 5/5 (60 dBuV) Max at: 66 kHz MIN: 3 kHz % above 75 kHz: 0,1288 Acquired: 2024/05/27 9:32:57 Total samples: 17075 Equivalent time: 0:14:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,4 dBr MIN: 3,1 dBr AVE: 3,93 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2024/05/27 9:32:55) Station: 105.50 MHz, signal: 5/5 (60 dBuV) 09:20 09:22 09:24 09:26 09:28 09:30 09:32 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality